Load Cell Item ID: #232


JL-03 (For bench scale)




Product Information:

Rated Capacities 50, 60, 100, 150, 200, 250, 300, 500, 600, 750, 800, 1000, 1200 (kg) Rated Output 2.0 mV/V±5% Non-linearity 0.02 %F.S Hysteresis 0.02 %F.S Repeatability 0.02 %F.S Creep (20min) 0.02 %F.S Temperature Effect On Output 0.002 %F.S/°C Temperature Effect On Zero 0.003 %F.S/°C Zero Balance ±0.0200 mV/V Input Impedance 390±15 Ω ; 410±15 [...]

Share

Item Description

Rated Capacities 50, 60, 100, 150, 200, 250, 300, 500, 600, 750, 800, 1000, 1200 (kg)
Rated Output 2.0 mV/V±5%
Non-linearity 0.02 %F.S
Hysteresis 0.02 %F.S
Repeatability 0.02 %F.S
Creep (20min) 0.02 %F.S
Temperature Effect On Output 0.002 %F.S/°C
Temperature Effect On Zero 0.003 %F.S/°C
Zero Balance ±0.0200 mV/V
Input Impedance 390±15 Ω ; 410±15 Ω
Output Impedance 350±5 Ω
Insulation Impedance ≥5000 MΩ
Safe Overload 150 %F.S
Ultimate Overload 200 %F.S
Operating Temperature Range -20°C~60°C
Recommended Excitation 5 ~ 12 VDC
Maximum Excitation 15 VDC
Construction Aluminum Alloy
Protection Class IP66 / IP67
Cable Φ 5 x 2 m
Platform Size 800 x 800 mm
Mode of Connection Red (EXC+) ,Black (EXC-) ,Green (SIG+) ,White (SIG-)